W DOC AIRBUS | TSM A320F

Loss of the ADF 2 Data Bus Identified by the EIS 2


TASK 34-53-00-810-808-A
Loss of the ADF 2 Data Bus Identified by the EIS 2


1. Possible Causes
  • [2RP2]
  • wiring of the BEARING OUTPUT 2 bus from the ADF receiver 2 (2RP2) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-740-002
Perform Electronic Instrument System (EIS) Input Test
AMM 31-60-00-740-007
GROUND SCANNING Test of the DMC
ASM 345301
AMM 34-53-31-000-002
Removal of the ADF Receiver
AMM 34-53-31-400-002
Installation of the ADF Receiver
3. Fault Confirmation
Subtask 34-53-00-865-066-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUCOM NAV/ADF/21RP2K02
Subtask 34-53-00-740-064-A ** ON A/C NOT FOR ALL
B. Test
   (1) Do the EIS input test AMM 31-60-00-740-002.
Subtask 34-53-00-740-064-C ** ON A/C NOT FOR ALL
B. Test
   (1) Do the Ground Scanning Test of the DMC AMM 31-60-00-740-007.
4. Fault Isolation
Subtask 34-53-00-810-059-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC2 : NO ADF2 DATA:
   (1) If the fault continues:
  • do a check and repair the wiring of the BEARING OUTPUT 2 bus from the ADF receiver 2 (2RP2) to the first terminal block ASM 345301.
Subtask 34-53-00-810-059-C ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC2 : ADF2(2RP2)/DMC2(1WT2)
   (1) If the fault continues:
  • do a check and repair the wiring of the BEARING OUTPUT 2 bus from the ADF receiver 2 (2RP2) to the first terminal block ASM 345301.
Subtask 34-53-00-740-065-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:33:26 UTC