W DOC AIRBUS | TSM A320F

Loss of the Control Source Data to the ATC/MODE S Transponder 2


TASK 34-52-00-810-812-A
Loss of the Control Source Data to the ATC/MODE S Transponder 2


1. Possible Causes
  • CTL UNIT-ATC/TCAS [3SH]
  • XPDR-ATC/MODE S, 2 [1SH2]
  • wiring of the CONTROL DATA bus from the ATC control unit (3SH) to the ATC/MODE S transponder 2 (1SH2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-52-00-740-004
BITE Test of the ATC
ASM 345201
AMM 34-52-12-000-001
Removal of the ATC/TCAS Control Unit
AMM 34-52-12-400-001
Installation of the ATC/TCAS Control Unit
AMM 34-52-33-000-001
Removal of the ATC/Mode S Transponder
AMM 34-52-33-400-001
Installation of the ATC/Mode S Transponder
3. Fault Confirmation
Subtask 34-52-00-740-072-A
A. Test
   (1) Do the BITE test of the ATC AMM 34-52-00-740-004.
4. Fault Isolation
Subtask 34-52-00-810-063-C
A. If the BITE test gives the maintenance message ATC CTL PNL(3SH)/ATC2(1SH2) :
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring of the CONTROL DATA bus from the ATC control unit (3SH) to the ATC/MODE S transponder 2 (1SH2) ASM 345201.
Subtask 34-52-00-740-073-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:23 UTC