Loss of the CFDIU Input Data to the ATC/MODE S Transponder 2
TASK 34-52-00-810-810-A
Loss of the CFDIU Input Data to the ATC/MODE S Transponder 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-52-00-740-068-A 4. Fault Isolation
Subtask 34-52-00-810-061-B
[Rev.8 from Aug 2018]
2026.04.04 04:33:23 UTC
Loss of the CFDIU Input Data to the ATC/MODE S Transponder 2
1. Possible Causes
- CFDIU [1TW]
- XPDR-ATC/MODE S, 2 [1SH2]
wiring of the MAINTENANCE DATA INPUT bus from the CFDIU (1TW) to the ATC/Mode S transponder 2 (1SH2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
| AMM 34-52-00-740-004 | BITE Test of the ATC |
| ASM 345201 | |
| AMM 34-52-33-000-001 | Removal of the ATC/Mode S Transponder |
| AMM 34-52-33-400-001 | Installation of the ATC/Mode S Transponder |
Subtask 34-52-00-740-068-A 4. Fault Isolation
Subtask 34-52-00-810-061-B
A. If the BITE test gives the maintenance message CFDIU (1TW) / ATC2 (1SH2) :
Subtask 34-52-00-740-069-A - replace the CFDIU [1TW] AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- replace the XPDR-ATC/MODE S, 2 [1SH2] AMM 34-52-33-000-001 and AMM 34-52-33-400-001.
- do a check and repair the
wiring of the MAINTENANCE DATA INPUT bus from the CFDIU (1TW) to the ATC/Mode S transponder 2 (1SH2) ASM 345201.
B. Do the test given in Para. 3.