W DOC AIRBUS | TSM A320F

Loss of the ADIRU Input Data to the ATC/MODE S Transponder 2


TASK 34-52-00-810-808-A
Loss of the ADIRU Input Data to the ATC/MODE S Transponder 2


1. Possible Causes
  • ADIRU-2 [1FP2]
  • XPDR-ATC/MODE S, 2 [1SH2]
  • wiring between the ADIRU 2 and the ATC/Mode S transponder 2
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-52-00-740-004
BITE Test of the ATC
ASM 345201
AMM 34-52-33-000-001
Removal of the ATC/Mode S Transponder
AMM 34-52-33-400-001
Installation of the ATC/Mode S Transponder
3. Fault Confirmation
Subtask 34-52-00-740-064-B
A. Test
   (1) Make sure that the Air Data Select switch 15FP is set to NORM.
   (2) Do the BITE test of the ATC AMM 34-52-00-740-004.
4. Fault Isolation
Subtask 34-52-00-810-059-B
A. If the test gives the maintenance message : ADIRU 2/3 (1FP2/3)/ATC2(1SH2)
   (1) If the fault continues :
   (2) If the fault continues :
  • do a check and repair the wiring between the ADIRU 2 and the ATC/Mode S transponder 2 for the Air Data Input 1 bus ASM 345201.
Subtask 34-52-00-740-065-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:40:26 UTC