Loss of the DME2 Data
TASK 34-51-00-810-830-A
Loss of the DME2 Data
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-51-00-740-086-A 4. Fault Isolation
Subtask 34-51-00-810-082-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:21 UTC
Loss of the DME2 Data
1. Possible Causes
- INTRG-DME, 2 [2SD2]
- wiring between the DME interrogator 2 and the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-51-00-740-002 | BITE Test of the DME |
| ASM 345101 | |
| AMM 34-51-33-000-001 | Removal of the DME Interrogator |
| AMM 34-51-33-400-001 | Installation of the DME Interrogator |
Subtask 34-51-00-740-086-A 4. Fault Isolation
Subtask 34-51-00-810-082-A
A. If the test gives the maintenance message DMC2/1 (1WT2/1)/DDRMI(1FN)/DME2(2SD2):
Subtask 34-51-00-740-087-A - swap the INTRG-DME, 2 [2SD2] and the DME interrogator 1 AMM 34-51-33-000-001 and AMM 34-51-33-400-001.
- replace the DME interrogator that you installed on side 1.
- remove the DME interrogator 2
- do a check and repair the wiring between the DME interrogator 2 and the first terminal block : for pins AB/3G, 3H of the DME interrogator 2 ASM 345101
- install the DME interrogator 2.
B. Do the test given in Para. 3.