Loss of the Audio Signal from the DME Interrogator 1
TASK 34-51-00-810-821-A
Loss of the Audio Signal from the DME Interrogator 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-51-00-710-050-A 4. Fault Isolation
Subtask 34-51-00-810-076-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:20 UTC
Loss of the Audio Signal from the DME Interrogator 1
1. Possible Causes
- INTRG-DME, 1 [2SD1]
- AMU [1RN]
wiring of the DME 1 AUDIO bus from the AMU (1RN) to the DME interrogator 1 (2SD1)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 23-51-34-000-001 | Removal of the Audio Management Unit (AMU) (1RN) |
| AMM 23-51-34-400-001 | Installation of the Audio Management Unit (AMU) (1RN) |
| AMM 34-51-00-710-001 | Operational Test of the DME |
| ASM 345101 | |
| AMM 34-51-33-000-001 | Removal of the DME Interrogator |
| AMM 34-51-33-400-001 | Installation of the DME Interrogator |
Subtask 34-51-00-710-050-A 4. Fault Isolation
Subtask 34-51-00-810-076-A
A. If there is no audio signal on the loud speakers during the test, when the DME 1 data are shown on the ND:
Subtask 34-51-00-710-051-A - replace the INTRG-DME, 1 [2SD1] AMM 34-51-33-000-001 and AMM 34-51-33-400-001.
- replace the AMU [1RN] AMM 23-51-34-000-001 and AMM 23-51-34-400-001.
- do a check and repair the
wiring of the DME 1 AUDIO bus from the AMU (1RN) to the DME interrogator 1 (2SD1) ASM 345101.
B. Do the test given in Para. 3.