Loss of the CFDIU Input Bus on the DME 2
TASK 34-51-00-810-820-A
Loss of the CFDIU Input Bus on the DME 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-51-00-740-080-A 4. Fault Isolation
Subtask 34-51-00-810-075-B
[Rev.8 from Aug 2018]
2026.04.04 04:33:20 UTC
Loss of the CFDIU Input Bus on the DME 2
1. Possible Causes
- INTRG-DME, 2 [2SD2]
wiring of the MAINTENANCE DATA INPUT bus from the DME interrogator 2 (2SD2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-51-00-740-002 | BITE Test of the DME |
| ASM 345101 | |
| AMM 34-51-33-000-001 | Removal of the DME Interrogator |
| AMM 34-51-33-400-001 | Installation of the DME Interrogator |
Subtask 34-51-00-740-080-A 4. Fault Isolation
Subtask 34-51-00-810-075-B
A. If the test gives the maintenance message CFDIU(1TW)/DME2(2SD2):
Subtask 34-51-00-740-081-A - replace the INTRG-DME, 2 [2SD2] AMM 34-51-33-000-001 and AMM 34-51-33-400-001.
- do a check and repair the
wiring of the MAINTENANCE DATA INPUT bus from the DME interrogator 2 (2SD2) to the first terminal block ASM 345101.
B. Do the test given in Para. 3.