W DOC AIRBUS | TSM A320F

BITE Test of the DME 2 Inoperative


TASK 34-51-00-810-818-A
BITE Test of the DME 2 Inoperative


1. Possible Causes
  • INTRG-DME, 2 [2SD2]
  • LGCIU-2 [5GA2]
  • wiring of the GND/AIR LOGIC discrete from the DME interrogator 2 (2SD2) to the LGCIU 2 (5GA2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 32-31-71-000-001
Removal of the LGCIU
AMM 32-31-71-400-001
Installation of the LGCIU
AMM 34-51-00-740-002
BITE Test of the DME
ASM 345101
AMM 34-51-33-000-001
Removal of the DME Interrogator
AMM 34-51-33-400-001
Installation of the DME Interrogator
3. Fault Confirmation
Subtask 34-51-00-740-076-A
A. Test
   (1) Not applicable, the fault is evident.
4. Fault Isolation
Subtask 34-51-00-810-073-A
A. If the BITE test of the DME 2 cannot be started on the MCDU:
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring of the GND/AIR LOGIC discrete from the DME interrogator 2 (2SD2) to the LGCIU 2 (5GA2) ASM 345101.
Subtask 34-51-00-740-077-A
B. Do the BITE test of the DME AMM 34-51-00-740-002.