W DOC AIRBUS | TSM A320F

BITE Test of the DME 1 Inoperative


TASK 34-51-00-810-817-A
BITE Test of the DME 1 Inoperative


1. Possible Causes
  • INTRG-DME, 1 [2SD1]
  • LGCIU-1 [5GA1]
  • wiring of the GND/AIR LOGIC discrete from the DME interrogator 1 (2SD1) to the LGCIU 1 (5GA1)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 32-31-71-000-001
Removal of the LGCIU
AMM 32-31-71-400-001
Installation of the LGCIU
AMM 34-51-00-740-002
BITE Test of the DME
ASM 345101
AMM 34-51-33-000-001
Removal of the DME Interrogator
AMM 34-51-33-400-001
Installation of the DME Interrogator
3. Fault Confirmation
Subtask 34-51-00-740-074-A
A. Test
   (1) Not applicable, the fault is evident.
4. Fault Isolation
Subtask 34-51-00-810-072-A
A. If the BITE test of the DME 1 cannot be started on the MCDU:
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring of the GND/AIR LOGIC discrete from the DME interrogator 1 (2SD1) to the LGCIU 1 (5GA1) ASM 345101.
Subtask 34-51-00-740-075-A
B. Do the BITE test of the DME AMM 34-51-00-740-002.
[Rev.8 from Aug 2018] 2026.04.04 04:33:20 UTC