W DOC AIRBUS | TSM A320F

DME 2 System Inoperative


TASK 34-51-00-810-816-A
DME 2 System Inoperative


1. Possible Causes
  • INTRG-DME, 2 [2SD2]
  • wiring of the DISTANCE DATA OUTPUT 2 bus from the DME interrogator 2 (2SD2) to the first terminal block
  • DMC-1 [1WT1]
  • wiring of the DME 2 INPUT bus from the DMC 1 (1WT1) to the first terminal block
  • DMC-3 [1WT3]
  • wiring of the DME 2 INPUT bus from the DMC 3 (1WT3) to the first terminal block
  • DMC-2 [1WT2]
  • wiring of the DME 2 INPUT bus from the DMC 2 (1WT2) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
AMM 34-51-00-720-001
Functional Test of the DME
AMM 34-51-00-740-002
BITE Test of the DME
ASM 345101
AMM 34-51-33-000-001
Removal of the DME Interrogator
AMM 34-51-33-400-001
Installation of the DME Interrogator
3. Fault Confirmation
Subtask 34-51-00-720-056-A
A. Test
   (1) Do the functional test of the DME AMM 34-51-00-720-001.
4. Fault Isolation
Subtask 34-51-00-810-069-A
A. If on the two NDs:
. the DME 2 data do not come into view
. the red flag is shown:
   (1) If the BITE test gives a maintenance message:
  • Do the trouble shooting procedure related to the maintenance message.
   (2) If the BITE test does not give a maintenance message:
     (a) If the fault continues:
  • do a check and repair the wiring of the DISTANCE DATA OUTPUT 2 bus from the DME interrogator 2 (2SD2) to the first terminal block ASM 345101.
Subtask 34-51-00-810-070-A
B. If on the CAPT ND only:
. the DME 2 data do not come into view
. the red flag is shown:
  • make sure that on the center pedestal, on the SWITCHING panel 8VU, the EIS DMC selector switch is at CAPT 3:
   (1) If no:
     (a) If the fault continues:
  • do a check and repair the wiring of the DME 2 INPUT bus from the DMC 1 (1WT1) to the first terminal block ASM 345101.
   (2) If yes:
     (a) If the fault continues:
  • do a check and repair the wiring of the DME 2 INPUT bus from the DMC 3 (1WT3) to the first terminal block ASM 345101.
Subtask 34-51-00-810-071-A
C. If on the F/O ND only:
. the DME 2 data do not come into view
. the red flag is shown:
  • make sure that on the center pedestal, on the SWITCHING panel 8VU, the EIS DMC selector switch is at F/O 3:
   (1) If no:
     (a) If the fault continues:
  • do a check and repair the wiring of the DME 2 INPUT bus from the DMC 2 (1WT2) to the first terminal block ASM 345101.
   (2) If yes:
     (a) If the fault continues:
  • do a check and repair the wiring of the DME 2 INPUT bus from the DMC 3 (1WT3) to the first terminal block ASM 345101.
Subtask 34-51-00-720-057-A
D. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:20 UTC