Loss of the DME 2 Data on the ND
TASK 34-51-00-810-814-A
Loss of the DME 2 Data on the ND
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-51-00-720-052-A 4. Fault Isolation
Subtask 34-51-00-810-065-A
[Rev.8 from Aug 2018]
2026.04.04 04:40:27 UTC
Loss of the DME 2 Data on the ND
1. Possible Causes
- INTRG-DME, 2 [2SD2]
- ANTENNA-DME, 2 [3SD2]
wiring from the DME antenna 2 (3SD2) to the DME interrogator 2 (2SD2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-51-00-720-001 | Functional Test of the DME |
| AMM 34-51-00-740-002 | BITE Test of the DME |
| ASM 345101 | |
| AMM 34-51-11-000-002 | Removal of the DME Antenna |
| AMM 34-51-11-400-002 | Installation of the DME Antenna |
| AMM 34-51-33-000-001 | Removal of the DME Interrogator |
| AMM 34-51-33-400-001 | Installation of the DME Interrogator |
Subtask 34-51-00-720-052-A 4. Fault Isolation
Subtask 34-51-00-810-065-A
A. If the DME 2 data do not come into view on the ND:
Subtask 34-51-00-720-053-A - do the BITE test of the DME AMM 34-51-00-740-002.
- Do the trouble shooting procedure related to the maintenance message.
- replace the INTRG-DME, 2 [2SD2] AMM 34-51-33-000-001 and AMM 34-51-33-400-001.
- replace the ANTENNA-DME, 2 [3SD2] AMM 34-51-11-000-002 and AMM 34-51-11-400-002.
- do a check and repair the
wiring from the DME antenna 2 (3SD2) to the DME interrogator 2 (2SD2) ASM 345101.
B. Do the test given in Para. 3.