Loss of the DME 2 Tuning Data
TASK 34-51-00-810-813-A
Loss of the DME 2 Tuning Data
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-51-00-740-072-A 4. Fault Isolation
Subtask 34-51-00-810-064-B
[Rev.8 from Aug 2018]
2026.04.04 04:33:20 UTC
Loss of the DME 2 Tuning Data
1. Possible Causes
- FMGC-2 [1CA2]
wiring of the FMGC OWN CB 1 bus from the FMGC 2 (1CA2) to the first terminal block - RMP-COM/NAV FREQ SEL, 2 [1RG2]
wiring of the DATA FROM FMGC bus from the COM/NAV FREQ SEL RMP 2 (1RG2) to the first terminal block wiring of the NAV DATA OUTPUT bus from the COM/NAV FREQ SEL RMP 2 (1RG2) to the first terminal block - INTRG-DME, 2 [2SD2]
wiring of the FREQ FUNCT SELECT DATA INP A bus from the DME interrogator 2 (2SD2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-83-34-000-001 | Removal of the FMGC |
| AMM 22-83-34-400-001 | Installation of the FMGC |
| ASM 228602 | |
| ASM 231301 | |
| AMM 23-13-13-000-001 | Removal of the Radio Management Panel (RMP) |
| AMM 23-13-13-400-001 | Installation of the Radio Management Panel (RMP) |
| AMM 34-14-00-740-001 | Interface Test of the IR |
| AMM 34-51-00-740-002 | BITE Test of the DME |
| ASM 345101 | |
| AMM 34-51-33-000-001 | Removal of the DME Interrogator |
| AMM 34-51-33-400-001 | Installation of the DME Interrogator |
| AMM 34-55-00-740-002 | BITE Test of the VOR/MKR |
Subtask 34-51-00-740-072-A 4. Fault Isolation
Subtask 34-51-00-810-064-B
A. If the test gives the maintenance message FMGC2(1CA2)/RMP2(1RG2)/DME2(2SD2):
Subtask 34-51-00-740-073-A - on the center pedestal, on the RMP 2, push the NAV and the VOR pushbutton switches (the green LED on these pushbutton switches comes on)
- do the BITE test of the DME AMM 34-51-00-740-002.
- do the Interface test of the IR (system 1) AMM 34-14-00-740-001.
- replace the FMGC-2 [1CA2] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- do a check and repair the
wiring of the FMGC OWN CB 1 bus from the FMGC 2 (1CA2) to the first terminal block ASM 228602.
- replace the RMP-COM/NAV FREQ SEL, 2 [1RG2] AMM 23-13-13-000-001 and AMM 23-13-13-400-001.
- do a check and repair the
wiring of the DATA FROM FMGC bus from the COM/NAV FREQ SEL RMP 2 (1RG2) to the first terminal block ASM 231301.
- do the BITE test of the VOR/MKR AMM 34-55-00-740-002.
- replace the RMP-COM/NAV FREQ SEL, 2 [1RG2] AMM 23-13-13-000-001 and AMM 23-13-13-400-001.
- do a check and repair the
wiring of the NAV DATA OUTPUT bus from the COM/NAV FREQ SEL RMP 2 (1RG2) to the first terminal block ASM 345101.
- replace the INTRG-DME, 2 [2SD2] AMM 34-51-33-000-001 and AMM 34-51-33-400-001.
- do a check and repair the
wiring of the FREQ FUNCT SELECT DATA INP A bus from the DME interrogator 2 (2SD2) to the first terminal block ASM 345101.
B. Do the test given in Para. 3.