Loss of the DME 1 Tuning Data
TASK 34-51-00-810-811-A
Loss of the DME 1 Tuning Data
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-51-00-740-070-A 4. Fault Isolation
Subtask 34-51-00-810-062-B
[Rev.8 from Aug 2018]
2026.04.04 04:33:20 UTC
Loss of the DME 1 Tuning Data
1. Possible Causes
- FMGC-1 [1CA1]
wiring of the FMGC OWN CB 1 bus from the FMGC 1 (1CA1) to the first terminal block - RMP-COM/NAV FREQ SEL, 1 [1RG1]
wiring of the DATA FROM FMGC bus from the COM/NAV FREQ SEL RMP 1 (1RG1) to the first terminal block wiring of the NAV DATA OUTPUT bus from the COM/NAV FREQ SEL RMP 1 (1RG1) to the first terminal block - INTRG-DME, 1 [2SD1]
wiring of the FREQ FUNCT SELECT DATA INP A bus from the DME interrogator 1 (2SD1) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-83-34-000-001 | Removal of the FMGC |
| AMM 22-83-34-400-001 | Installation of the FMGC |
| ASM 228602 | |
| ASM 231301 | |
| AMM 23-13-13-000-001 | Removal of the Radio Management Panel (RMP) |
| AMM 23-13-13-400-001 | Installation of the Radio Management Panel (RMP) |
| AMM 34-14-00-740-001 | Interface Test of the IR |
| AMM 34-51-00-740-002 | BITE Test of the DME |
| ASM 345101 | |
| AMM 34-51-33-000-001 | Removal of the DME Interrogator |
| AMM 34-51-33-400-001 | Installation of the DME Interrogator |
| AMM 34-55-00-740-002 | BITE Test of the VOR/MKR |
Subtask 34-51-00-740-070-A 4. Fault Isolation
Subtask 34-51-00-810-062-B
A. If the test gives the maintenance message FMGC1(1CA1)/RMP1(1RG1)/DME1(2SD1):
Subtask 34-51-00-740-071-A - on the center pedestal, on the RMP 1, push the NAV and the VOR pushbutton switches (the green LED on these pushbutton switches comes on)
- do the BITE test of the DME AMM 34-51-00-740-002.
- do the Interface test of the IR (system 1) AMM 34-14-00-740-001.
- replace the FMGC-1 [1CA1] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- do a check and repair the
wiring of the FMGC OWN CB 1 bus from the FMGC 1 (1CA1) to the first terminal block ASM 228602.
- replace the RMP-COM/NAV FREQ SEL, 1 [1RG1] AMM 23-13-13-000-001 and AMM 23-13-13-400-001.
- do a check and repair the
wiring of the DATA FROM FMGC bus from the COM/NAV FREQ SEL RMP 1 (1RG1) to the first terminal block ASM 231301.
- do the BITE test of the VOR/MKR AMM 34-55-00-740-002.
- replace the RMP-COM/NAV FREQ SEL, 1 [1RG1] AMM 23-13-13-000-001 and AMM 23-13-13-400-001.
- do a check and repair the
wiring of the NAV DATA OUTPUT bus from the COM/NAV FREQ SEL RMP 1 (1RG1) to the first terminal block ASM 345101.
- replace the INTRG-DME, 1 [2SD1] AMM 34-51-33-000-001 and AMM 34-51-33-400-001.
- do a check and repair the
wiring of the FREQ FUNCT SELECT DATA INP A bus from the DME interrogator 1 (2SD1) to the first terminal block ASM 345101.
B. Do the test given in Para. 3.