W DOC AIRBUS | TSM A320F

Loss of the DME 1 Tuning Data


TASK 34-51-00-810-811-A
Loss of the DME 1 Tuning Data


1. Possible Causes
  • FMGC-1 [1CA1]
  • wiring of the FMGC OWN CB 1 bus from the FMGC 1 (1CA1) to the first terminal block
  • RMP-COM/NAV FREQ SEL, 1 [1RG1]
  • wiring of the DATA FROM FMGC bus from the COM/NAV FREQ SEL RMP 1 (1RG1) to the first terminal block
  • wiring of the NAV DATA OUTPUT bus from the COM/NAV FREQ SEL RMP 1 (1RG1) to the first terminal block
  • INTRG-DME, 1 [2SD1]
  • wiring of the FREQ FUNCT SELECT DATA INP A bus from the DME interrogator 1 (2SD1) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-83-34-000-001
Removal of the FMGC
AMM 22-83-34-400-001
Installation of the FMGC
ASM 228602
ASM 231301
AMM 23-13-13-000-001
Removal of the Radio Management Panel (RMP)
AMM 23-13-13-400-001
Installation of the Radio Management Panel (RMP)
AMM 34-14-00-740-001
Interface Test of the IR
AMM 34-51-00-740-002
BITE Test of the DME
ASM 345101
AMM 34-51-33-000-001
Removal of the DME Interrogator
AMM 34-51-33-400-001
Installation of the DME Interrogator
AMM 34-55-00-740-002
BITE Test of the VOR/MKR
3. Fault Confirmation
Subtask 34-51-00-740-070-A
A. Test
Do the BITE test of the DME AMM 34-51-00-740-002.
4. Fault Isolation
Subtask 34-51-00-810-062-B
A. If the test gives the maintenance message FMGC1(1CA1)/RMP1(1RG1)/DME1(2SD1):
  • on the center pedestal, on the RMP 1, push the NAV and the VOR pushbutton switches (the green LED on these pushbutton switches comes on)
  • do the BITE test of the DME AMM 34-51-00-740-002.
   (1) If the test does not give the maintenance message FMGC1(1CA1)/RMP1(1RG1)/ DME1(2SD1):
     (a) If the Interface test of the IR gives a maintenance message related of a FMGC 1 failure:
       1 If the fault continues:
  • do a check and repair the wiring of the FMGC OWN CB 1 bus from the FMGC 1 (1CA1) to the first terminal block ASM 228602.
     (b) If the Interface test of the IR does not give a maintenance message related of a FMGC 1 failure:
       1 If the fault continues:
  • do a check and repair the wiring of the DATA FROM FMGC bus from the COM/NAV FREQ SEL RMP 1 (1RG1) to the first terminal block ASM 231301.
   (2) If the test gives again the maintenance message FMGC1(1CA1)/RMP1(1RG1)/ DME1(2SD1):
     (a) If the BITE test gives a maintenance message related of a RMP 1 failure:
       1 If the fault continues:
  • do a check and repair the wiring of the NAV DATA OUTPUT bus from the COM/NAV FREQ SEL RMP 1 (1RG1) to the first terminal block ASM 345101.
     (b) If the BITE test does not give a maintenance message related of a RMP 1 failure:
       1 If the fault continues:
  • do a check and repair the wiring of the FREQ FUNCT SELECT DATA INP A bus from the DME interrogator 1 (2SD1) to the first terminal block ASM 345101.
Subtask 34-51-00-740-071-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:20 UTC