Loss of the DME 2 Data Bus Identified by the CFDS


TASK 34-51-00-810-810-A
Loss of the DME 2 Data Bus Identified by the CFDS


1. Possible Causes
  • INTRG-DME, 2 [2SD2]
  • wiring of the DISTANCE DATA OUTPUT 2 bus from the DME interrogator 2 (2SD2) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-00-869-002
Procedure for the Class 3 Fault Reading
ASM 345101
AMM 34-51-33-000-001
Removal of the DME Interrogator
AMM 34-51-33-400-001
Installation of the DME Interrogator
3. Fault Confirmation
Subtask 34-51-00-865-057-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUCOM NAV/DME/21SD2K06
Subtask 34-51-00-740-068-A
B. Test
On the CFDS MENU page, get access to the AVIONICS STATUS page AMM 31-32-00-869-002.
4. Fault Isolation
Subtask 34-51-00-810-061-A
A. If the test gives the maintenance message NO DME 2 DATA:
   (1) If the fault continues:
  • do a check and repair the wiring of the DISTANCE DATA OUTPUT 2 bus from the DME interrogator 2 (2SD2) to the first terminal block ASM 345101.
Subtask 34-51-00-740-069-A
B. Do the test given in Para. 3.B.