Loss of the DME 2 Data Bus Identified by the CFDS
TASK 34-51-00-810-810-A
Loss of the DME 2 Data Bus Identified by the CFDS
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-51-00-865-057-A
Subtask 34-51-00-810-061-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:20 UTC
Loss of the DME 2 Data Bus Identified by the CFDS
1. Possible Causes
- INTRG-DME, 2 [2SD2]
wiring of the DISTANCE DATA OUTPUT 2 bus from the DME interrogator 2 (2SD2) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-32-00-869-002 | Procedure for the Class 3 Fault Reading |
| ASM 345101 | |
| AMM 34-51-33-000-001 | Removal of the DME Interrogator |
| AMM 34-51-33-400-001 | Installation of the DME Interrogator |
Subtask 34-51-00-865-057-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 34-51-00-740-068-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | COM NAV/DME/2 | 1SD2 | K06 |
Subtask 34-51-00-810-061-A
A. If the test gives the maintenance message NO DME 2 DATA:
Subtask 34-51-00-740-069-A - replace the INTRG-DME, 2 [2SD2] AMM 34-51-33-000-001 and AMM 34-51-33-400-001.
- do a check and repair the
wiring of the DISTANCE DATA OUTPUT 2 bus from the DME interrogator 2 (2SD2) to the first terminal block ASM 345101.
B. Do the test given in Para. 3.B.