Loss of the DME 1 Data Bus Identified by the EIS 2
TASK 34-51-00-810-804-A
Loss of the DME 1 Data Bus Identified by the EIS 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-51-00-865-051-A
Subtask 34-51-00-810-055-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:18 UTC
Loss of the DME 1 Data Bus Identified by the EIS 2
1. Possible Causes
- INTRG-DME, 1 [2SD1]
wiring of the DISTANCE DATA OUTPUT 2 bus from the DME interrogator 1 (2SD1) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-007 | GROUND SCANNING Test of the DMC |
| ASM 345101 | |
| AMM 34-51-33-000-001 | Removal of the DME Interrogator |
| AMM 34-51-33-400-001 | Installation of the DME Interrogator |
Subtask 34-51-00-865-051-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 34-51-00-740-056-A ** ON A/C NOT FOR ALL Subtask 34-51-00-740-056-B ** ON A/C NOT FOR ALL 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | NAV/DME/1 | 1SD1 | G14 |
Subtask 34-51-00-810-055-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC 2 : NO DME 1 DATA:
Subtask 34-51-00-810-055-B ** ON A/C NOT FOR ALL - replace the INTRG-DME, 1 [2SD1] AMM 34-51-33-000-001 and AMM 34-51-33-400-001.
- do a check and repair the
wiring of the DISTANCE DATA OUTPUT 2 bus from the DME interrogator 1 (2SD1) to the first terminal block ASM 345101.
A. If the test gives the maintenance message DMC 2 : DME1(2SD2/DMC2(1WT2)
Subtask 34-51-00-740-057-A - replace the INTRG-DME, 1 [2SD1] AMM 34-51-33-000-001 and AMM 34-51-33-400-001.
- do a check and repair the
wiring of the DISTANCE DATA OUTPUT 2 bus from the DME interrogator 1 (2SD1) to the first terminal block ASM 345101.
B. Do the test given in Para. 3.B.