W DOC AIRBUS | TSM A320F

Loss of the DME 1 Data Bus Identified by the EIS 2


TASK 34-51-00-810-804-A
Loss of the DME 1 Data Bus Identified by the EIS 2


1. Possible Causes
  • INTRG-DME, 1 [2SD1]
  • wiring of the DISTANCE DATA OUTPUT 2 bus from the DME interrogator 1 (2SD1) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-740-002
Perform Electronic Instrument System (EIS) Input Test
AMM 31-60-00-740-007
GROUND SCANNING Test of the DMC
ASM 345101
AMM 34-51-33-000-001
Removal of the DME Interrogator
AMM 34-51-33-400-001
Installation of the DME Interrogator
3. Fault Confirmation
Subtask 34-51-00-865-051-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUNAV/DME/11SD1G14
Subtask 34-51-00-740-056-A ** ON A/C NOT FOR ALL
B. Test
   (1) Do the EIS input test AMM 31-60-00-740-002.
Subtask 34-51-00-740-056-B ** ON A/C NOT FOR ALL
B. Test
   (1) Do the Ground Scanning Test of the DMC AMM 31-60-00-740-007.
4. Fault Isolation
Subtask 34-51-00-810-055-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC 2 : NO DME 1 DATA:
   (1) If the fault continues:
  • do a check and repair the wiring of the DISTANCE DATA OUTPUT 2 bus from the DME interrogator 1 (2SD1) to the first terminal block ASM 345101.
Subtask 34-51-00-810-055-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC 2 : DME1(2SD2/DMC2(1WT2)
   (1) If the fault continues:
  • do a check and repair the wiring of the DISTANCE DATA OUTPUT 2 bus from the DME interrogator 1 (2SD1) to the first terminal block ASM 345101.
Subtask 34-51-00-740-057-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:33:18 UTC