Failure of the DME Interrogator 2
TASK 34-51-00-810-802-A
Failure of the DME Interrogator 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-51-00-865-059-A
Subtask 34-51-00-810-052-B
[Rev.8 from Aug 2018]
2026.04.04 04:33:18 UTC
Failure of the DME Interrogator 2
1. Possible Causes
- INTRG-DME, 2 [2SD2]
short to ground at the wiring between the circuit breaker (1SD2) and the DME receiver 2 (2SD2) - C/B-COM NAV/DME/2 [1SD2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-51-00-740-002 | BITE Test of the DME |
| ASM 345101 | |
| AMM 34-51-33-000-001 | Removal of the DME Interrogator |
| AMM 34-51-33-400-001 | Installation of the DME Interrogator |
Subtask 34-51-00-865-059-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 34-51-00-740-052-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | COM NAV/DME/2 | 1SD2 | K06 |
B. Test
(1) If the circuit breaker (1SD2) trips, refer to Para. 4. C. of this trouble shooting procedure.
(2) Do the BITE test of the DME AMM 34-51-00-740-002.
4. Fault Isolation(1) If the circuit breaker (1SD2) trips, refer to Para. 4. C. of this trouble shooting procedure.
(2) Do the BITE test of the DME AMM 34-51-00-740-002.
- If the BITE test is not possible, refer to Para. 4. B. of this trouble shooting procedure.
Subtask 34-51-00-810-052-B
A. If the circuit breaker (1SD2) is closed, and if the BITE test gives the maintenance message DME2 (2SD2):
Subtask 34-51-00-810-053-A - replace the INTRG-DME, 2 [2SD2] AMM 34-51-33-000-001 and AMM 34-51-33-400-001.
B. If the circuit breaker (1SD2) is closed and if the BITE test is not possible
Subtask 34-51-00-810-079-A - do a check for 115VAC at pin AC/1 of the DME receiver 2.
- do a check of the wiring of the 115VAC signal from circuit breaker (1SD2) to DME receiver 2 (2SD2) ASM 345101.
- repair the above wiring.
- replace the C/B-NAV/DME2 (1SD2).
- do a check of the wiring of the ground signal at DME receiver 2 pin AC/7.
- repair the above wiring.
C. If the circuit breaker (1SD2) is open:
AMM 34-51-33-400-001.
Subtask 34-51-00-740-053-A - close this circuit breaker.
- remove the INTRG-DME, 2 [2SD2] AMM 34-51-33-000-001.
- close the circuit breaker (1SD2).
- install the DME receiver 2 AMM 34-51-33-400-001
- replace the DME receiver 2 AMM 34-51-33-000-001 and AMM 34-51-33-400-001.
- do a check for a
short to ground at the wiring between the circuit breaker (1SD2) and the DME receiver 2 (2SD2) ASM 345101.
- repair the above wiring.
- replace the C/B-COM NAV/DME/2 [1SD2] .
AMM 34-51-33-400-001.
D. Do the test given in Para. 3.