W DOC AIRBUS | TSM A320F

Loss of the Weather Radar 2 Input Data


TASK 34-48-00-810-842-A
Loss of the Weather Radar 2 Input Data


1. Possible Causes
  • [1SQ2]
  • wiring of the weather radar 2 DATA INPUT bus
  • GPWC [1WZ]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-41-33-000-004
Removal of the Weather Radar Transceiver
AMM 34-41-33-400-003
Installation of the Weather Radar Transceiver
AMM 34-48-00-740-002
BITE Test of the GPWS
ASM 344802
AMM 34-48-34-000-001
Removal of the GPWC
AMM 34-48-34-400-001
Installation of the GPWC
3. Fault Confirmation
Subtask 34-48-00-740-096-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of the GPWS AMM 34-48-00-740-002.
4. Fault Isolation
Subtask 34-48-00-810-106-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message: WXR2 (1SQ2) BUS HAZARD/GPWC (1WZ)
  • If the second weather radar transceiver is not installed:
    . On the center pedestal, on the weather radar control unit, set the SYS switch to 1. The message goes out of view.
  • If the second weather radar transceiver is installed:
    . Replace [1SQ2] AMM 34-41-33-000-004 and AMM 34-41-33-400-003.
   (1) If the fault continues:
     (a) Do a check and repair the wiring of the weather radar 2 DATA INPUT bus between:
  • Pins AB/6C, AB/6D of the GPWC and pins AB/5J, AB/6J of weather radar transceiver 2 (1SQ2) ASM 344802.
       1 If the fault continues:
Subtask 34-48-00-740-097-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:17 UTC