Permanent Display of Terrain Data on F/O ND
TASK 34-48-00-810-835-A
Permanent Display of Terrain Data on F/O ND
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-48-00-740-082-A 4. Fault Isolation
Subtask 34-48-00-810-099-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:17 UTC
Permanent Display of Terrain Data on F/O ND
1. Possible Causes
- GPWC [1WZ]
- P/BSW-TERR ON ND,F/O [30WZ2]
wiring of the TERRAIN POP-UP F/O discrete between the GPWC (1WZ) and the TERR ON ND, F/O pushbutton switch (30WZ2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ESPM 2045110 | |
| AMM 34-48-00-740-002 | BITE Test of the GPWS |
| ASM 344802 | |
| AMM 34-48-34-000-001 | Removal of the GPWC |
| AMM 34-48-34-400-001 | Installation of the GPWC |
Subtask 34-48-00-740-082-A 4. Fault Isolation
Subtask 34-48-00-810-099-A
A. If the BITE test gives the maintenance message:
FO TERR ON ND PB SW (30WZ2)/GPWC (1WZ)
Subtask 34-48-00-740-083-A FO TERR ON ND PB SW (30WZ2)/GPWC (1WZ)
- on the LDG GEAR CTL & IND PNL (402VU), make sure that the TERR ON ND, F/O pushbutton switch (30WZ2) is not pushed (the ON legend is off)
- do a check for ground at pin AA/1B of the GPWC ASM 344802.
- replace the GPWC [1WZ] AMM 34-48-34-000-001 and AMM 34-48-34-400-001.
- replace the P/BSW-TERR ON ND,F/O [30WZ2] ESPM 2045110.
- do a check and repair the
wiring of the TERRAIN POP-UP F/O discrete between the GPWC (1WZ) and the TERR ON ND, F/O pushbutton switch (30WZ2) : for pin AA/1B of the GPWC ASM 344802.
B. Do the test given in Para. 3.