Permanent Display of Terrain Data on CAPT ND
TASK 34-48-00-810-834-A
Permanent Display of Terrain Data on CAPT ND
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-48-00-740-104-A 4. Fault Isolation
Subtask 34-48-00-810-110-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:17 UTC
Permanent Display of Terrain Data on CAPT ND
1. Possible Causes
- GPWC [1WZ]
- P/BSW-TERR ON ND,CAPT [30WZ1]
wiring of the TERRAIN POP-UP CAPT discrete between the GPWC (1WZ) and the TERR ON ND, CAPT pushbutton switch (30WZ1)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ESPM 2045110 | |
| AMM 34-48-00-740-002 | BITE Test of the GPWS |
| ASM 344802 | |
| AMM 34-48-34-000-001 | Removal of the GPWC |
| AMM 34-48-34-400-001 | Installation of the GPWC |
Subtask 34-48-00-740-104-A 4. Fault Isolation
Subtask 34-48-00-810-110-A
A. If the BITE test gives the maintenance message:
CAPT TERR ON ND PB SW (30WZ1)/GPWC (1WZ)
Subtask 34-48-00-740-105-A CAPT TERR ON ND PB SW (30WZ1)/GPWC (1WZ)
- on the TERR ON ND PNL (403VU), make sure that the TERR ON ND, CAPT pushbutton switch (30WZ1) is not pushed (the ON legend is off)
- do a check for ground at pin AA/1A of the GPWC ASM 344802.
- replace the GPWC [1WZ] AMM 34-48-34-000-001 and AMM 34-48-34-400-001.
- replace the P/BSW-TERR ON ND,CAPT [30WZ1] ESPM 2045110.
- do a check and repair the
wiring of the TERRAIN POP-UP CAPT discrete between the GPWC (1WZ) and the TERR ON ND, CAPT pushbutton switch (30WZ1) : for pin AA/1A of the GPWC ASM 344802.
B. Do the test given in Para. 3.