Inhibition of the Flap Condition not Possible
TASK 34-48-00-810-827-A
Inhibition of the Flap Condition not Possible
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-48-00-710-075-A
Subtask 34-48-00-810-089-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:16 UTC
Inhibition of the Flap Condition not Possible
1. Possible Causes
wiring of the GPWS/FLAP MODE pushbutton switch (7WZ) - P/BSW-GPWS/FLAP MODE [7WZ]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ESPM 2045110 | |
| ASM 344801 |
Subtask 34-48-00-710-075-A
A. Test
Not applicable, you cannot confirm this fault on the ground.
4. Fault IsolationNot applicable, you cannot confirm this fault on the ground.
Subtask 34-48-00-810-089-A
A. Do the procedure:
- on the GPWS section of panel 21VU, make sure that the GPWS/FLAP MODE pushbutton switch (7WZ) is pushed (the OFF legend is on)
- on the center pedestal, on the panel 114VU, put the flap and slat control lever in the 0 position
- make sure that there is ground at pin AB/9C of the GPWC (1WZ).
- do a check of the
wiring of the GPWS/FLAP MODE pushbutton switch (7WZ) :
. pin A/B3 to the ground point
. pin A/B1 to GPWC (1WZ) pin AB/9C
ASM 344801.
- repair the above wirings.
- replace the P/BSW-GPWS/FLAP MODE [7WZ] ESPM 2045110.