Ground Proximity Warning System Inoperative
TASK 34-48-00-810-825-A
Ground Proximity Warning System Inoperative
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-48-00-865-056-A
Subtask 34-48-00-810-077-B
[Rev.8 from Aug 2018]
2026.04.04 04:33:16 UTC
Ground Proximity Warning System Inoperative
1. Possible Causes
- GPWC [1WZ]
wiring of the ILS DATA INPUT bus from the GPWC (1WZ) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-36-00-740-003 | BITE Test of the MMR |
| AMM 34-36-00-740-004 | BITE Test of the ILS |
| AMM 34-36-00-740-006 | BITE Test of the MMR |
| ASM 344801 | |
| AMM 34-48-34-000-001 | Removal of the GPWC |
| AMM 34-48-34-400-001 | Installation of the GPWC |
Subtask 34-48-00-865-056-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 34-48-00-710-072-C ** ON A/C NOT FOR ALL Subtask 34-48-00-710-072-F ** ON A/C NOT FOR ALL Subtask 34-48-00-710-072-G ** ON A/C NOT FOR ALL 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | EIS/GPWS/115VAC | 3WZ | P07 |
Subtask 34-48-00-810-077-B
A. If the test gives a maintenance message:
Subtask 34-48-00-810-078-B - do the trouble shooting procedure related to the maintenance message.
B. If there is no fault:
Subtask 34-48-00-710-073-A - replace the GPWC [1WZ] AMM 34-48-34-000-001 and AMM 34-48-34-400-001.
- do a check and repair the
wiring of the ILS DATA INPUT bus from the GPWC (1WZ) to the first terminal block ASM 344801.
C. Do the test given in Para. 3.