Temporary Inhibition of the Glide Slope Mode Inoperative
TASK 34-48-00-810-819-A
Temporary Inhibition of the Glide Slope Mode Inoperative
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-48-00-710-061-D ** ON A/C NOT FOR ALL
Subtask 34-48-00-810-071-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:15 UTC
Temporary Inhibition of the Glide Slope Mode Inoperative
1. Possible Causes
- GPWC [1WZ]
wiring of the GLIDE SLOPE MANUAL INHIBIT discrete from the GPWC (1WZ) to the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 34-48-00-810-817-A | Self-Test Function of the GPWS Inoperative |
| AMM 34-48-00-710-001 | Operational Test of GPWS Ground Self-test Function |
| ASM 344801 | |
| AMM 34-48-34-000-001 | Removal of the GPWC |
| AMM 34-48-34-400-001 | Installation of the GPWC |
Subtask 34-48-00-710-061-D ** ON A/C NOT FOR ALL
A. Test
(1) Do the operational test of Enhanced GPWS ground self-test function AMM 34-48-00-710-001.
(2) Make sure that you can do the test with the two GPWS/G/S pushbutton switches (4WZ and 5WZ).
Subtask 34-48-00-710-061-F ** ON A/C NOT FOR ALL (1) Do the operational test of Enhanced GPWS ground self-test function AMM 34-48-00-710-001.
(2) Make sure that you can do the test with the two GPWS/G/S pushbutton switches (4WZ and 5WZ).
A. Test
(1) Do the operational test of Enhanced GPWS ground self-test function AMM 34-48-00-710-001.
(2) Make sure that you can do the test with the two PULL UP/GPWS pushbutton switches (4WZ and 5WZ).
4. Fault Isolation(1) Do the operational test of Enhanced GPWS ground self-test function AMM 34-48-00-710-001.
(2) Make sure that you can do the test with the two PULL UP/GPWS pushbutton switches (4WZ and 5WZ).
Subtask 34-48-00-810-071-A
A. Do the procedure:
(1) If the test is not possible with one or two pushbutton switches:
Subtask 34-48-00-710-062-A (1) If the test is not possible with one or two pushbutton switches:
- refer to the procedure (Ref. TSM TASK 34-48-00-810-817).
- replace the GPWC [1WZ] AMM 34-48-34-000-001 and AMM 34-48-34-400-001.
- do a check and repair the
wiring of the GLIDE SLOPE MANUAL INHIBIT discrete from the GPWC (1WZ) to the first terminal block ASM 344801.
B. Do the test given in Para. 3.