W DOC AIRBUS | TSM A320F

Loss of the FMGC1 Input


TASK 34-48-00-810-807-A
Loss of the FMGC1 Input


1. Possible Causes
  • GPWC [1WZ]
  • wiring of the FMGC DATA INPUT bus (AB 10C/10D) from the GPWC (1WZ) to the first terminal block
  • wiring of the FMGC DATA INPUT bus (AB 12C/12D) from the GPWC (1WZ) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-48-00-740-002
BITE Test of the GPWS
ASM 344801
ASM 344802
AMM 34-48-34-000-001
Removal of the GPWC
AMM 34-48-34-400-001
Installation of the GPWC
3. Fault Confirmation
Subtask 34-48-00-740-062-C
A. Test
   (1) Do the BITE test of the Enhanced GPWS AMM 34-48-00-740-002.
4. Fault Isolation
Subtask 34-48-00-810-057-D
A. If the BITE test gives the maintenance message FMCG1 (1CA1)/GPWC (1WZ):
   (1) If the fault continues:
  • do a check and repair the wiring of the FMGC DATA INPUT bus (AB 10C/10D) from the GPWC (1WZ) to the first terminal block ASM 344801.
  • do a check and repair the wiring of the FMGC DATA INPUT bus (AB 12C/12D) from the GPWC (1WZ) to the first terminal block ASM 344802.
Subtask 34-48-00-740-063-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:14 UTC