Loss of the IR1 Bus 3 Output Identified by the TCAS


TASK 34-43-00-810-835-A
Loss of the IR1 Bus 3 Output Identified by the TCAS


1. Possible Causes
  • ADIRU-1 [1FP1]
  • wiring of the INERTIAL REFERENCE OUTPUT BUS 3 bus from the ADIRU1 (1FP1) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
ASM 341401
AMM 34-43-00-740-004
Bite Test of the T2CAS
3. Fault Confirmation
Subtask 34-43-00-740-113-A
A. Test
   (1) Do the BITE test of the T2CAS (TCAS part) AMM 34-43-00-740-004.
4. Fault Isolation
Subtask 34-43-00-810-089-A
A. If the test gives the maintenance message ADIRU1 (1FP1)/TCAS (100SG):
   (1) If the fault continues:
  • do a check and repair the wiring of the INERTIAL REFERENCE OUTPUT BUS 3 bus from the ADIRU1 (1FP1) to the first terminal block ASM 341401.
Subtask 34-43-00-740-114-A
B. Do the test given in Para. 3.