Loss of the Suppressor Function between ATC1 and TCAS
TASK 34-43-00-810-829-A
Loss of the Suppressor Function between ATC1 and TCAS
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-43-00-865-057-A
Subtask 34-43-00-810-081-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:13 UTC
Loss of the Suppressor Function between ATC1 and TCAS
1. Possible Causes
- CMPTR-TCAS [1SG]
- suppressor coaxial cable
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-43-00-740-001 | BITE Test of the TCAS |
| AWM 344305 | |
| AMM 34-43-34-000-001 | Removal of the TCAS Computer |
| AMM 34-43-34-400-001 | Installation of the TCAS Computer |
| AMM 34-52-00-740-004 | BITE Test of the ATC |
| AWM 345203 |
Subtask 34-43-00-865-057-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 34-43-00-740-098-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | COM NAV/ATC/1 | 5SH1 | G11 |
| 121VU | COM NAV/TCAS | 4SG | K10 |
| 121VU | COM NAV/ATC/2 | 5SH2 | K07 |
B. ATC1 Test
On the center pedestal, on the ATC/TCAS control unit, set the ATC1 to on and do the BITE test of the ATC (system 1) AMM 34-52-00-740-004.
Subtask 34-43-00-740-100-A 4. Fault IsolationOn the center pedestal, on the ATC/TCAS control unit, set the ATC1 to on and do the BITE test of the ATC (system 1) AMM 34-52-00-740-004.
Subtask 34-43-00-810-081-A ** ON A/C NOT FOR ALL
A. If the ATC1 test gives the maintenance message ATC-1:NO DATA FROM TCAS, and if the TCAS test gives the maintenance message TCAS (1SG):
Subtask 34-43-00-810-081-B ** ON A/C NOT FOR ALL - on the center pedestal, on the ATC/TCAS control unit, set the ATC2 to on and do the BITE test of the ATC (system 2) AMM 34-52-00-740-004.
- replace the CMPTR-TCAS [1SG] AMM 34-43-34-000-001 and AMM 34-43-34-400-001
- if the fault continues, do a check and repair the suppressor coaxial cable from the TCAS computer (1SG) pin AC/12 to the connector 150VC AWM 344305.
- if the test is OK, do a check and repair the suppressor coaxial cable from the ATC transponder 1 (1SH1) pin AC/12 to the connector 150VC AWM 345203.
A. If the ATC1 test gives the maintenance message TCAS(1SG)/ATC1(1SH1) and if the TCAS test gives the maintenance message TCAS (1SG):
Subtask 34-43-00-740-102-A - on the center pedestal, on the ATC/TCAS control unit, set the ATC2 to on and do the BITE test of the ATC (system 2) AMM 34-52-00-740-004.
- replace the CMPTR-TCAS [1SG] AMM 34-43-34-000-001 and AMM 34-43-34-400-001
- if the fault continues, do a check and repair the suppressor coaxial cable from the TCAS computer (1SG) pin AC/12 to the connector 150VC AWM 344305.
- if the test is OK, do a check and repair the suppressor coaxial cable from the ATC transponder 1 (1SH1) pin AC/12 to the connector 150VC AWM 345203.
B. Do the test given in Para. 3.