Loss of the Aural Advisories in the Loud Speaker(s)


TASK 34-43-00-810-827-A
Loss of the Aural Advisories in the Loud Speaker(s)


1. Possible Causes
  • LOUD SPEAKER-CAPT [7WW]
  • wiring of the CAPT loud speaker (7WW)
  • LOUD SPEAKER-F/O [8WW]
  • wiring of the F/O loud speaker (8WW)
  • CMPTR-TCAS [1SG]
  • RELAY-RCDR/CVR TEST (20RK)
  • wiring of the AUDIO OUTPUT discretes from the TCAS computer (1SG) to the RCDR/CVR test relay (20RK)
  • wiring of the RCDR/CVR test relay (20RK)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 31-53-00-810-922-A
Failure of the Captain Loud Speaker
TSM TASK 31-53-00-810-923-A
Failure of the First Officer Loud Speaker
AMM 31-53-21-000-001
Removal of the Loudspeakers
AMM 31-53-21-400-001
Installation of the Loudspeakers
AMM 34-43-00-740-001
BITE Test of the TCAS
ASM 344301
AMM 34-43-34-000-001
Removal of the TCAS Computer
AMM 34-43-34-400-001
Installation of the TCAS Computer
3. Fault Confirmation
Subtask 34-43-00-740-096-A
A. Test
   (1) Do the BITE test of the TCAS AMM 34-43-00-740-001 and make sure that you can hear the synthesized voice message in the two loud speakers.
4. Fault Isolation
Subtask 34-43-00-810-078-A
A. If you cannot hear the synthesized voice message:
   (1) In the CAPT loud speaker only:
     (a) If the fault continues:
  • do a check and repair the wiring of the CAPT loud speaker (7WW):
    . pin A/R to the first terminal block
    . pin A/S to the first terminal block
    ASM 344301.
   (2) In the F/O loud speaker only:
     (a) If the fault continues:
  • do a check and repair the wiring of the F/O loud speaker (8WW):
    . pin A/R to the first terminal block
    . pin A/S to the first terminal block
    ASM 344301.
   (3) In the two loud speakers:
     (a) If the fault continues:
  • replace the RELAY-RCDR/CVR TEST (20RK).
       1 If the fault continues:
  • do a check of the wiring of the AUDIO OUTPUT discretes from the TCAS computer (1SG) to the RCDR/CVR test relay (20RK) ASM 344301.
         a If there is no continuity:
  • repair the above wiring.
         b If there is continuity:
  • do a check and repair the wiring of the RCDR/CVR test relay (20RK):
    . pin A/B to the first terminal block
    . pin A/C to the first terminal block
    ASM 344301.
     (b) If the fault continues:
Subtask 34-43-00-740-097-A
B. Do the test given in Para. 3.