Loss of the Manual Operating Modes of the TCAS
TASK 34-43-00-810-825-A
Loss of the Manual Operating Modes of the TCAS
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 34-43-00-740-092-A 4. Fault Isolation
Subtask 34-43-00-810-075-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:13 UTC
Loss of the Manual Operating Modes of the TCAS
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-43-00-740-001 | BITE Test of the TCAS |
| AMM 34-43-34-000-001 | Removal of the TCAS Computer |
| AMM 34-43-34-400-001 | Installation of the TCAS Computer |
| AMM 34-52-12-000-001 | Removal of the ATC/TCAS Control Unit |
| AMM 34-52-12-400-001 | Installation of the ATC/TCAS Control Unit |
Subtask 34-43-00-740-092-A 4. Fault Isolation
Subtask 34-43-00-810-075-A
A. If the test gives the maintenance message ATC-TCAS CTL PNL (3SH)/TCAS (1SG):
Subtask 34-43-00-740-093-A - replace the CTL UNIT-ATC/TCAS [3SH] AMM 34-52-12-000-001 and AMM 34-52-12-400-001.
- replace the CMPTR-TCAS [1SG] AMM 34-43-34-000-001 and AMM 34-43-34-400-001.
B. Do the test given in Para. 3.