W DOC AIRBUS | TSM A320F

Loss of the RA/TA DISPLAY 1 Bus Identified by the ECAM1


TASK 34-43-00-810-802-A
Loss of the RA/TA DISPLAY 1 Bus Identified by the ECAM1


1. Possible Causes
  • CMPTR-TCAS [1SG]
  • wiring of the RA/TA DISPLAY 1 bus from the TCAS computer (1SG) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 344301
AMM 34-43-34-000-001
Removal of the TCAS Computer
AMM 34-43-34-400-001
Installation of the TCAS Computer
3. Fault Confirmation
Subtask 34-43-00-865-066-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUCOM NAV/TCAS4SGK10
Subtask 34-43-00-710-050-A
B. Test
   (1) Do the operational test of the central warning systems AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 34-43-00-810-052-A
A. If the test gives the maintenance message FWC1: NO DATA FROM TCAS:
   (1) If the fault continues:
  • do a check and repair the wiring of the RA/TA DISPLAY 1 bus from the TCAS computer (1SG) to the first terminal block ASM 344301.
Subtask 34-43-00-710-051-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:12 UTC