Fan of the RA Transceiver 2 Inoperative
TASK 34-42-00-810-823-A
Fan of the RA Transceiver 2 Inoperative
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-42-00-700-052-A 4. Fault Isolation
Subtask 34-42-00-810-074-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:09 UTC
Fan of the RA Transceiver 2 Inoperative
1. Possible Causes
- XCVR-RA, 2 [2SA2]
- FAN-RA XCVR2 [3SA2]
wiring between the fan of the RA transceiver 2 (3SA2) and the RA transceiver 2 (2SA2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-42-00-750-001 | Operational Test and Detailed Inspection for Contamination of the Radio Altimeter Fan |
| ASM 344202 | |
| AMM 34-42-33-000-001 | Removal of the Radio Altimeter Transceiver |
| AMM 34-42-33-400-001 | Installation of the Radio Altimeter Transceiver |
| AMM 34-42-45-000-001 | Removal of the Radio Altimeter-Transceiver Fan |
| AMM 34-42-45-400-001 | Installation of the Radio Altimeter-Transceiver Fan |
Subtask 34-42-00-700-052-A 4. Fault Isolation
Subtask 34-42-00-810-074-A
A. If the fan does not operate correctly:
Subtask 34-42-00-700-053-A - replace the XCVR-RA, 2 [2SA2] AMM 34-42-33-000-001 and AMM 34-42-33-400-001.
- replace the FAN-RA XCVR2 [3SA2] AMM 34-42-45-000-001 and AMM 34-42-45-400-001.
- do a check and repair the
wiring between the fan of the RA transceiver 2 (3SA2) and the RA transceiver 2 (2SA2) ASM 344202.
B. Do the test given in Para. 3.