Failure of the Radio Altimeter (RA) Transceiver 2
TASK 34-42-00-810-802-A
Failure of the Radio Altimeter (RA) Transceiver 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-42-00-865-051-A
Subtask 34-42-00-810-052-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:07 UTC
Failure of the Radio Altimeter (RA) Transceiver 2
1. Possible Causes
- XCVR-RA, 2 [2SA2]
short to ground at the wiring between the circuit breaker (1SA2) and the RA transceiver 2 (2SA2). C/B-COM NAV/RAD ALTM/2
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 31-32-00-810-934-A | Failure of the Digital Links |
| AMM 34-42-00-740-002 | BITE Test of the Radio Altimeter |
| ASM 344202 | |
| AMM 34-42-33-000-001 | Removal of the Radio Altimeter Transceiver |
| AMM 34-42-33-400-001 | Installation of the Radio Altimeter Transceiver |
Subtask 34-42-00-865-051-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 34-42-00-740-052-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | COM NAV/RAD ALTM/2 | 1SA2 | K12 |
B. Test
(1) If the circuit breaker (1SA2) trips, refer to Para. 4. C. of this trouble shooting procedure.
(2) Do the BITE test of the radio altimeter AMM 34-42-00-740-002.
4. Fault Isolation(1) If the circuit breaker (1SA2) trips, refer to Para. 4. C. of this trouble shooting procedure.
(2) Do the BITE test of the radio altimeter AMM 34-42-00-740-002.
- If the BITE test is not possible, refer to Para. 4. B. of this trouble shooting procedure.
Subtask 34-42-00-810-052-A ** ON A/C NOT FOR ALL
A. If the circuit breaker (1SA2) is closed, and if the BITE test gives the maintenance message LRRA-2 TRANCEIVER.
Subtask 34-42-00-810-052-B ** ON A/C NOT FOR ALL - replace the XCVR-RA, 2 [2SA2] AMM 34-42-33-000-001 and AMM 34-42-33-400-001.
A. If the circuit breaker (1SA2) is closed, and if the BITE test gives the maintenance message RA 2 (2SA2).
Subtask 34-42-00-810-053-A - replace the XCVR-RA, 2 [2SA2] AMM 34-42-33-000-001 and AMM 34-42-33-400-001.
B. If the circuit breaker (1SA2) is closed and if the BITE test is not possible
1 do the trouble shooting procedure (Ref. TSM TASK 31-32-00-810-934) related to:
Subtask 34-42-00-810-083-A - do a check for 115VAC at pin AC/8 of the RA transceiver 2.
- do a check of the wiring of the 115VAC signal from circuit breaker (1SA2) to RA transceiver 2 (2SA2) ASM 344202.
- repair the above wiring.
- replace the C/B-COM NAV/RAD ALTM/2 (1SA2).
- do a check of the wiring of the ground signal at RA transceiver 2 pin AC/3.
- repair the above wiring.
1 do the trouble shooting procedure (Ref. TSM TASK 31-32-00-810-934) related to:
- the output Bus signal ALTITUDE BUS 1 (2) ASM 344202.
C. If the circuit breaker (1SA2) is open:
AMM 34-42-33-400-001.
Subtask 34-42-00-740-053-A - close this circuit breaker.
- remove the XCVR-RA, 2 [2SA2] AMM 34-42-33-000-001.
- close the circuit breaker (1SA2).
- install the RA transceiver 2 AMM 34-42-33-400-001
- replace the RA transceiver 2 AMM 34-42-33-000-001 and AMM 34-42-33-400-001.
- do a check for a
short to ground at the wiring between the circuit breaker (1SA2) and the RA transceiver 2 (2SA2). ASM 344202.
- repair the above wiring.
- replace the
C/B-COM NAV/RAD ALTM/2 .
AMM 34-42-33-400-001.
D. Do the test given in Para. 3.B.