W DOC AIRBUS | TSM A320F

Loss of Qualifiers B1/B2 on the Weather Radar Transceiver 1


TASK 34-41-00-810-850-A
Loss of Qualifiers B1/B2 on the Weather Radar Transceiver 1


1. Possible Causes
  • XCVR-WEATHER RADAR, 1 [1SQ1]
  • wiring between the weather radar transceiver 1 and the EIU-1
  • wiring between the weather radar transceiver 1 and the EIU-2
  • diode module 1805VD
  • diode module 1802VD
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 344100
AMM 34-41-00-740-002
BITE Test of the Weather Radar
AMM 34-41-33-000-004
Removal of the Weather Radar Transceiver
AMM 34-41-33-400-003
Installation of the Weather Radar Transceiver
3. Fault Confirmation
Subtask 34-41-00-740-138-A ** ON A/C NOT FOR ALL
A. Test
Do the BITE test of the weather radar (system 1) AMM 34-41-00-740-002
4. Fault Isolation
Subtask 34-41-00-810-113-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message QUALIFIER B1/2WXR1(1SQ1):
   (1) Replace the XCVR-WEATHER RADAR, 1 [1SQ1] AMM 34-41-33-000-004 and AMM 34-41-33-400-003.
   (2) If the fault continues:
  • do a check and repair the wiring between the weather radar transceiver 1 and the EIU-1 ASM 344100 : pin AB/11B and pin AB/7A
  • do a check and repair the wiring between the weather radar transceiver 1 and the EIU-2 ASM 344100 : pin AB/12B and pin AB/7A.
   (3) If the fault continues:
  • do a check and repair the diode module 1805VD : pin A/25 and pin A/10
  • do a check and repair the diode module 1802VD : pin A/44 and pin A/43.
   (4) If the fault continues:
  • refer to the trouble shooting procedures of the EIUs.
Subtask 34-41-00-740-139-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
5. Close-up
Subtask 34-41-00-860-050-A ** ON A/C NOT FOR ALL
A. Put the Aircraft back to its Initial Configuration
[Rev.8 from Aug 2018] 2026.04.04 04:33:07 UTC