W DOC AIRBUS | TSM A320F

Loss of the Enhanced GPWC Data on the Weather Radar Transceiver 1


TASK 34-41-00-810-848-A
Loss of the Enhanced GPWC Data on the Weather Radar Transceiver 1


1. Possible Causes
  • XCVR-WEATHER RADAR, 1 [1SQ1]
  • GPWC [1WZ]
  • wiring between the weather radar transceiver 1 and the GPWC
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 344100
AMM 34-41-00-740-002
BITE Test of the Weather Radar
AMM 34-41-33-000-004
Removal of the Weather Radar Transceiver
AMM 34-41-33-400-003
Installation of the Weather Radar Transceiver
AMM 34-48-34-000-001
Removal of the GPWC
AMM 34-48-34-400-001
Installation of the GPWC
3. Fault Confirmation
Subtask 34-41-00-740-134-A
A. Test
Do the BITE test of the weather radar system 1 AMM 34-41-00-740-002.
4. Fault Isolation
Subtask 34-41-00-810-111-A
A. If the test gives the maintenance message:
GPWC(1WZ)/ WXR1(1SQ1)
   (1) Replace the XCVR-WEATHER RADAR, 1 [1SQ1] AMM 34-41-33-000-004 and AMM 34-41-33-400-003.
   (2) If the fault continues:
   (3) If the fault continues:
  • do a check and repair the wiring between the weather radar transceiver 1 and the GPWC : pins AB/9G, 9H and pins AA/2A, 2B ASM 344100.
5. Close-up
Subtask 34-41-00-740-135-A
A. Do the test given in para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:06 UTC