W DOC AIRBUS | TSM A320F

Result of the BITE Test of the Weather Radar 1 not Satisfactory on CAPT and F/O NDs/PFDs


TASK 34-41-00-810-840-A
Result of the BITE Test of the Weather Radar 1 not Satisfactory on CAPT and F/O NDs/PFDs


1. Possible Causes
  • XCVR-WEATHER RADAR, 1 [1SQ1]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-41-00-740-002
BITE Test of the Weather Radar
ASM 344101
AMM 34-41-33-000-004
Removal of the Weather Radar Transceiver
AMM 34-41-33-400-003
Installation of the Weather Radar Transceiver
3. Fault Confirmation
Subtask 34-41-00-740-118-A
A. Test
   (1) Do the BITE test of the weather radar 1 AMM 34-41-00-740-002.
4. Fault Isolation
Subtask 34-41-00-810-101-A
A. If the test gives the maintenance message DMC1/2/3(1WT1/2/3)/WXR1(1SQ1):
   (1) Replace the XCVR-WEATHER RADAR, 1 [1SQ1] AMM 34-41-33-000-004 and AMM 34-41-33-400-003.
   (2) If the fault continues:
  • do a check of the wiring between weather radar transceiver 1 (1SQ1) pins AB/2G, 3G and terminal block 1851VT38 pins J, D and between weather radar transceiver 1 (1SQ1) pins AB/2D, 3D and terminal block 1851VT39 pins D, J ASM 344101.
5. Close-up
Subtask 34-41-00-740-119-A
A. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:33:06 UTC