W DOC AIRBUS | TSM A320F

WR1 Test Inoperative


TASK 34-41-00-810-822-A
WR1 Test Inoperative


1. Possible Causes
  • XCVR-WEATHER RADAR, 1 [1SQ1]
  • LGCIU-2 [5GA2]
  • wiring of the GROUND AIR discrete from the LGCIU2 (5GA2) to the weather radar transceiver 1 (1SQ1)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 32-31-71-000-001
Removal of the LGCIU
AMM 32-31-71-400-001
Installation of the LGCIU
ASM 344101
AMM 34-41-33-000-004
Removal of the Weather Radar Transceiver
AMM 34-41-33-400-003
Installation of the Weather Radar Transceiver
3. Fault Confirmation
Subtask 34-41-00-710-050-A
A. Test
Not applicable, the fault is evident.
4. Fault Isolation
Subtask 34-41-00-810-076-A
A. If you cannot start the WR1 test on the MCDU:
  • do a check for ground at pin AB/10K of the weather radar transceiver 1 (1SQ1).
   (1) If there is no ground:
   (2) If there is ground:
     (a) If there is still ground:
  • do a check and repair the wiring of the GROUND AIR discrete from the LGCIU2 (5GA2) to the weather radar transceiver 1 (1SQ1) ASM 344101.