W DOC AIRBUS | TSM A320F

Incorrect Pin Programming of MMR2


TASK 34-36-00-810-902-A
Incorrect Pin Programming of MMR2


1. Possible Causes
  • the MMR2 pin programming wiring
  • MMR-2 [40RT2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-36-00-740-003
BITE Test of the MMR
AWM 343601
AMM 34-36-31-000-001
Removal of the ILS Receiver
AMM 34-36-31-400-001
Installation of the ILS Receiver
3. Fault Confirmation
Subtask 34-36-00-740-209-A ** ON A/C NOT FOR ALL
A. Test
   (1) Do the BITE test of MMR2 AMM 34-36-00-740-003.
4. Fault Isolation
Subtask 34-36-00-810-173-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message PIN PROG/MMR2 (40RT2):
  • Do a check of the wiring of MMR2 (40RT2) pin programming AWM 343601 on MMR2 pins AB/4H, 4J, 4K, 5D, 5E, 5H, 5J, 6C, 6J.
   (1) If the wiring is not correct:
  • Repair the MMR2 pin programming wiring AWM 343601.
   (2) If the wiring is correct:
Subtask 34-36-00-740-210-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:04 UTC