Incorrect Pin Programming of MMR1
TASK 34-36-00-810-901-A
Incorrect Pin Programming of MMR1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-36-00-740-207-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-36-00-810-172-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:04 UTC
Incorrect Pin Programming of MMR1
1. Possible Causes
- the MMR1 pin programming wiring
- MMR-1 [40RT1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-36-00-740-003 | BITE Test of the MMR |
| AWM 343601 | |
| AMM 34-36-31-000-001 | Removal of the ILS Receiver |
| AMM 34-36-31-400-001 | Installation of the ILS Receiver |
Subtask 34-36-00-740-207-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-36-00-810-172-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message PIN PROG/MMR1 (40RT1):
Subtask 34-36-00-740-208-A ** ON A/C NOT FOR ALL - Do a check of the wiring of MMR1 (40RT1) pin programming AWM 343601 on MMR1 pins AB/4H, 4J, 4K, 5D, 5E, 5H, 5J, 6C, 6J.
- Repair the MMR1 pin programming wiring AWM 343601.
- Replace MMR-1 [40RT1] AMM 34-36-31-000-001 AMM 34-36-31-400-001.
B. Do the test given in Para. 3.