Incorrect Test Tune Inhibit Discrete Condition sent to MMR2
TASK 34-36-00-810-900-A
Incorrect Test Tune Inhibit Discrete Condition sent to MMR2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 34-36-00-740-205-A 4. Fault Isolation
Subtask 34-36-00-810-171-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:04 UTC
Incorrect Test Tune Inhibit Discrete Condition sent to MMR2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-83-34-000-001 | Removal of the FMGC |
| AMM 22-83-34-400-001 | Installation of the FMGC |
| AMM 34-36-00-740-003 | BITE Test of the MMR |
| AWM 343601 | |
| AWM 343631 | |
| AMM 34-36-31-000-001 | Removal of the ILS Receiver |
| AMM 34-36-31-400-001 | Installation of the ILS Receiver |
Subtask 34-36-00-740-205-A 4. Fault Isolation
Subtask 34-36-00-810-171-A
A. If the test gives the maintenance message FMGC2(1CA2)/MMR2(40RT2):
Subtask 34-36-00-740-206-A - Do a check for a short to the ground at pin AB/15F of MMR2 AWM 343631.
- Replace MMR-2 [40RT2] AMM 34-36-31-000-001 AMM 34-36-31-400-001.
- Do a check and repair the wiring from MMR2 (40RT2) pin AB/15F to FMGC2 (1CA2) pin AB/15K AWM 343601.
- Replace FMGC-2 [1CA2] AMM 22-83-34-000-001 AMM 22-83-34-400-001.
B. Do the test given in Para. 3.