Bad Data from the CFDIU Detected by the ILS2
TASK 34-36-00-810-889-A
Bad Data from the CFDIU Detected by the ILS2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-36-00-740-184-A 4. Fault Isolation
Subtask 34-36-00-810-155-A
Subtask 34-36-00-740-185-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:03 UTC
Bad Data from the CFDIU Detected by the ILS2
1. Possible Causes
- CFDIU [1TW]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-32-00-740-002 | BITE Test of the Centralized Fault Display Interface Unit (CFDIU) |
| ASM 313203 | |
| AMM 31-32-34-000-001 | Removal of the CFDIU |
| AMM 31-32-34-400-001 | Installation of the CFDIU |
| AMM 34-36-00-740-002 | BITE Test of the ILS |
Subtask 34-36-00-740-184-A 4. Fault Isolation
Subtask 34-36-00-810-155-A
A. If the test gives the maintenance message ILS2 BAD DATA FROM CFDIU:
5. Close-up- replace the CFDIU [1TW] , AMM 31-32-34-000-001 and AMM 31-32-34-400-001.
- do a check and repair the wiring from the CFDIU (1TW) pins AB/2H, 2J to the first terminal block , ASM 313203.
Subtask 34-36-00-740-185-A