W DOC AIRBUS | TSM A320F

Bad Data from the CFDIU Detected by the ILS2


TASK 34-36-00-810-889-A
Bad Data from the CFDIU Detected by the ILS2


1. Possible Causes
  • CFDIU [1TW]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-32-00-740-002
BITE Test of the Centralized Fault Display Interface Unit (CFDIU)
ASM 313203
AMM 31-32-34-000-001
Removal of the CFDIU
AMM 31-32-34-400-001
Installation of the CFDIU
AMM 34-36-00-740-002
BITE Test of the ILS
3. Fault Confirmation
Subtask 34-36-00-740-184-A
A. Test
   (1) Do the BITE test of the CFDIU AMM 31-32-00-740-002.
4. Fault Isolation
Subtask 34-36-00-810-155-A
A. If the test gives the maintenance message ILS2 BAD DATA FROM CFDIU:
   (1) If the fault continues:
  • do a check and repair the wiring from the CFDIU (1TW) pins AB/2H, 2J to the first terminal block , ASM 313203.
5. Close-up
Subtask 34-36-00-740-185-A
A. Do the BITE test of the ILS2 AMM 34-36-00-740-002
[Rev.8 from Aug 2018] 2026.04.04 04:33:03 UTC