W DOC AIRBUS | TSM A320F

Loss of the MLS Landing Antenna 2 Signal


TASK 34-36-00-810-881-A
Loss of the MLS Landing Antenna 2 Signal


1. Possible Causes
  • MMR-2 [40RT2]
  • coaxial cable between the MMR2 and the MLS landing antenna 2
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 343600
AMM 34-36-00-740-003
BITE Test of the MMR
AMM 34-36-31-000-001
Removal of the ILS Receiver
AMM 34-36-31-000-002
AMM 34-36-31-400-001
Installation of the ILS Receiver
AMM 34-36-31-400-002
3. Fault Confirmation
Subtask 34-36-00-740-174-A
A. Test
4. Fault Isolation
Subtask 34-36-00-810-150-B
A. If the test gives the maintenance message from the MMR2
MLS LANDING ANT2 (57RT2)/ COAX CABLE MMR2 (4ORT2):
   (1) Replace the MMR-2 [40RT2] AMM 34-36-31-000-001 and AMM 34-36-31-400-001.
     (a) If the fault continues:
  • remove the MMR2 AMM 34-36-31-000-002
  • disconnect the coaxial cable from the MLS landing antenna 2
  • make sure that there is continuity on the coaxial cable between the MMR2 and the MLS landing antenna 2 ASM 343600
  • replace the coaxial cable if necessary
  • make sure that there is discontinuity between the core and the shield of the coaxial cable of the MLS landing antenna 2
  • repair if necessary
  • install the MMR2 AMM 34-36-31-400-002
  • connect the coaxial cable to the MLS landing antenna 2
  • disconnect the coaxial cable from the MLS Landing Antenna 2
  • make sure that there is continuity on the coaxial cable of the MLS Landing Antenna 2 ASM 343600
  • replace the coaxial cable if necessary
  • make sure that there is discontinuity between the core and the shied of the coaxial cable of the MLS Landing Antenna 2
  • repair it if necessary
  • Install the receiver MMR2 AMM 34-36-31-400-002
  • connect the coaxial cable of the MLS Landing Antenna 2.
5. Close-up
Subtask 34-36-00-740-175-A
A. Do the test given in para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:03 UTC