W DOC AIRBUS | TSM A320F

Loss of the MMR1 data on the ADIRU2


TASK 34-36-00-810-877-A
Loss of the MMR1 data on the ADIRU2


1. Possible Causes
  • MMR-1 [40RT1]
  • ADIRU-2 [1FP2]
  • wiring from the MMR1 to the ADIRU2
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
AMM 34-14-00-740-001
Interface Test of the IR
ASM 343602
AMM 34-36-31-000-001
Removal of the ILS Receiver
AMM 34-36-31-400-001
Installation of the ILS Receiver
3. Fault Confirmation
Subtask 34-36-00-740-166-A
A. Test
   (1) Do the Interface test of the IR (system 2) AMM 34-14-00-740-001.
4. Fault Isolation
Subtask 34-36-00-810-146-B
A. If the test gives the maintenance message MMR1-GPSSU1(40RT1-1SN1)/ ADIRU2(1FP2):
NOTE: In this case the GPSSU1 message is for the GPS part of the MMR1.
   (1) If the fault continues:
     (a) If the fault continues:
  • do a check and repair the wiring from the MMR1 to the ADIRU2 :
    pins AB/2J, 2K to pins AB/7C, 8C for the GNSS INPUT 2 DATA bus and pins AB/2G, 2H to pins AB/1C, 2C for the GNSS INPUT 2 TIME MARK bus ASM 343602.
Subtask 34-36-00-740-167-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:02 UTC