Reset of the MMR2 after Initialization of the FMGC2
TASK 34-36-00-810-871-A
Reset of the MMR2 after Initialization of the FMGC2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 34-36-00-740-154-A Subtask 34-36-00-865-071-A
Subtask 34-36-00-810-138-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:02 UTC
Reset of the MMR2 after Initialization of the FMGC2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-36-00-740-003 | BITE Test of the MMR |
Subtask 34-36-00-740-154-A Subtask 34-36-00-865-071-A
B. Table of the circuit breakers used in this procedure:
4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/MMR/2 | 42RT2 | K09 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/MMR/2 | 42RT2 | L07 |
Subtask 34-36-00-810-138-A
A. If the test gives the maintenance message
FMGC1(1CA1) BUS MMR/MMR2(40RT2):
Open and close after a short time the circuit breaker 42RT2.
Subtask 34-36-00-740-155-A FMGC1(1CA1) BUS MMR/MMR2(40RT2):
Open and close after a short time the circuit breaker 42RT2.
B. Do the test given in Para. 3.