W DOC AIRBUS | TSM A320F

Reset of the MMR2 after Initialization of the FMGC2


TASK 34-36-00-810-871-A
Reset of the MMR2 after Initialization of the FMGC2


1. Possible Causes

2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-36-00-740-003
BITE Test of the MMR
3. Fault Confirmation
Subtask 34-36-00-740-154-A
A. Test
Do the BITE test of the MMR (system 2) AMM 34-36-00-740-003.
Subtask 34-36-00-865-071-A
B. Table of the circuit breakers used in this procedure:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUCOM NAV/MMR/242RT2K09
** ON A/C NOT FOR ALL
121VUCOM NAV/MMR/242RT2L07
4. Fault Isolation
Subtask 34-36-00-810-138-A
A. If the test gives the maintenance message
FMGC1(1CA1) BUS MMR/MMR2(40RT2):
Open and close after a short time the circuit breaker 42RT2.
Subtask 34-36-00-740-155-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:02 UTC