Failure of the MMR2 without Cockpit Effect
TASK 34-36-00-810-869-A
Failure of the MMR2 without Cockpit Effect
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-36-00-740-150-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-36-00-810-136-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:33:02 UTC
Failure of the MMR2 without Cockpit Effect
1. Possible Causes
- MMR-2 [40RT2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-36-00-740-003 | BITE Test of the MMR |
| AMM 34-36-31-000-001 | Removal of the ILS Receiver |
| AMM 34-36-31-400-001 | Installation of the ILS Receiver |
Subtask 34-36-00-740-150-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 34-36-00-810-136-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message MMR2(40RT2):
XA0X, XA1X, XA2X, XA3X, XA4X, XA5X, XA6X, XA7X, XA8X, XA9X, XAAX, XABX, XACX, XADX, XAEX, XAFX, XB0X, XB1X, XB2X, XB3X, XB4X or X8BX
Subtask 34-36-00-740-151-A ** ON A/C NOT FOR ALL - on the MCDU, push the line key adjacent to the maintenance message class number to get access to the trouble shooting data and read the related fault code.
- make a record of the fault code.
NOTE: Use only the second and third digits of the fault code(s).
(1) If the trouble shooting data give one of the fault codes that follow. XA0X, XA1X, XA2X, XA3X, XA4X, XA5X, XA6X, XA7X, XA8X, XA9X, XAAX, XABX, XACX, XADX, XAEX, XAFX, XB0X, XB1X, XB2X, XB3X, XB4X or X8BX
- no maintenance action is necessary.
- replace the MMR-2 [40RT2] AMM 34-36-31-000-001 and AMM 34-36-31-400-001.
B. Do the test given in Para. 3.