W DOC AIRBUS | TSM A320F

Failure of the MMR1 without Cockpit Effect


TASK 34-36-00-810-868-A
Failure of the MMR1 without Cockpit Effect


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-36-00-740-003
BITE Test of the MMR
AMM 34-36-31-000-001
Removal of the ILS Receiver
AMM 34-36-31-400-001
Installation of the ILS Receiver
3. Fault Confirmation
Subtask 34-36-00-740-152-A ** ON A/C NOT FOR ALL
A. Test
Do the BITE test of the MMR1 AMM 34-36-00-740-003.
4. Fault Isolation
Subtask 34-36-00-810-137-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message MMR1(40RT1):
  • on the MCDU, push the line key adjacent to the maintenance message class number to get access to the trouble shooting data and read the related fault code.
  • make a record of the fault code.
NOTE: Use only the second and third digits of the fault code(s).
   (1) If the trouble shooting data give one of the fault codes that follow:
XA0X, XA1X, XA2X, XA3X, XA4X, XA5X, XA6X, XA7X, XA8X, XA9X, XAAX, XABX, XACX, XADX, XAEX, XAFX, XB0X, XB1X, XB2X, XB3X, XB4X or X8BX
  • no maintenance action is necessary.
   (2) If the trouble shooting data do not give one of these fault codes:
Subtask 34-36-00-740-153-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:02 UTC