Loss of the ADIRU2 Data on the MMR2
TASK 34-36-00-810-858-A
Loss of the ADIRU2 Data on the MMR2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 34-36-00-740-132-A 4. Fault Isolation
Subtask 34-36-00-810-122-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:01 UTC
Loss of the ADIRU2 Data on the MMR2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-36-00-740-003 | BITE Test of the MMR |
| ASM 343602 | |
| AMM 34-36-31-000-001 | Removal of the ILS Receiver |
| AMM 34-36-31-400-001 | Installation of the ILS Receiver |
Subtask 34-36-00-740-132-A 4. Fault Isolation
Subtask 34-36-00-810-122-A
A. If the test gives the maintenance message ADIRU2(1FP2)/MMR2(40RT2):
Subtask 34-36-00-740-133-A - swap the ADIRU-2 [1FP2] and the ADIRU-1 (1FP1) AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- replace the ADIRU that you installed on side 1.
- swap the MMR-1 [40RT1] and the MMR-2 (40RT2) AMM 34-36-31-000-001 and AMM 34-36-31-400-001.
- replace the MMR that you installed on side 1.
- do a check and repair the wiring between the ADIRU2 and the MMR2 for pins AB/5E, 6E and AB/8A, 8B ASM 343602.
B. Do the test given in Para. 3.