Loss of the ADIRU3 Data on the MMR1 and/or MMR2
TASK 34-36-00-810-856-A
Loss of the ADIRU3 Data on the MMR1 and/or MMR2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-36-00-740-128-A 4. Fault Isolation
Subtask 34-36-00-810-120-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:01 UTC
Loss of the ADIRU3 Data on the MMR1 and/or MMR2
1. Possible Causes
- ADIRU-3 [1FP3]
- wiring between the ADIRU3 and the first terminal block
- MMR-1 [40RT1]
wiring between the MMR1 and the first terminal block: - MMR-2 [40RT2]
wiring between the MMR2 and the first terminal block:
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
| AMM 34-36-00-740-003 | BITE Test of the MMR |
| ASM 343602 | |
| AMM 34-36-31-000-001 | Removal of the ILS Receiver |
| AMM 34-36-31-000-002 | |
| AMM 34-36-31-400-001 | Installation of the ILS Receiver |
| AMM 34-36-31-400-002 |
Subtask 34-36-00-740-128-A 4. Fault Isolation
Subtask 34-36-00-810-120-A
A. If the tests give the maintenance messages
ADIRU3(1FP3)/MMR1(40RT1) and ADIRU3(1FP3)/MMR2(40RT2):
Subtask 34-36-00-810-124-A ADIRU3(1FP3)/MMR1(40RT1) and ADIRU3(1FP3)/MMR2(40RT2):
- replace the ADIRU-3 [1FP3] AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
- do a check and repair the wiring between the ADIRU3 and the first terminal block for pins AB/10C, 11C of the ADIRU3 ASM 343602.
B. If the test of the MMR1 gives the maintenance message ADIRU3(1FP3)/MMR1(40RT1):
Subtask 34-36-00-810-125-A - swap the MMR-1 [40RT1] and the MMR-2 (40RT2) AMM 34-36-31-000-001 and AMM 34-36-31-400-001.
- replace the MMR that you installed on side 2.
- do a check and repair the
wiring between the MMR1 and the first terminal block: for pins AB/8G, 8H of the MMR1 ASM 343602.
C. If the test of the MMR2 gives the maintenance message ADIRU3(1FP3)/MMR2(40RT2):
Subtask 34-36-00-740-129-A - swap the MMR-2 [40RT2] and the MMR-1 (40RT1) AMM 34-36-31-000-002 and AMM 34-36-31-400-002.
- replace the MMR that you installed on side 1.
- do a check and repair the
wiring between the MMR2 and the first terminal block: for pins AB/8G, 8H of the MMR2 ASM 343602.
D. Do the test given in Para. 3.