MMR2 Test cannot be started
TASK 34-36-00-810-853-A
MMR2 Test cannot be started
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-36-00-740-122-A 4. Fault Isolation
Subtask 34-36-00-810-117-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:01 UTC
MMR2 Test cannot be started
1. Possible Causes
- MMR-2 [40RT2]
- LGCIU-2 [5GA2]
wiring between the MMR2(40RT2) and the LGCIU2(5GA2) - FMGC-2 [1CA2]
wiring between the MMR2(40RT2) and the FMGC2(1CA2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-83-34-000-001 | Removal of the FMGC |
| AMM 22-83-34-400-001 | Installation of the FMGC |
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
| AMM 34-36-00-740-003 | BITE Test of the MMR |
| ASM 343601 | |
| AMM 34-36-31-000-001 | Removal of the ILS Receiver |
| AMM 34-36-31-400-001 | Installation of the ILS Receiver |
Subtask 34-36-00-740-122-A 4. Fault Isolation
Subtask 34-36-00-810-117-A
A. If the test gives the maintenance message
LGCIU2(5GA2)/FMGC2(1CA2)/ MMR2(40RT2):
Subtask 34-36-00-740-123-A LGCIU2(5GA2)/FMGC2(1CA2)/ MMR2(40RT2):
- do a check for a short to ground at pins AB/4A, 15F of the MMR-2 [40RT2] ASM 343601.
- replace the MMR-2 [40RT2] AMM 34-36-31-000-001 and AMM 34-36-31-400-001.
- replace the LGCIU-2 [5GA2] AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
- do a check and repair the
wiring between the MMR2(40RT2) and the LGCIU2(5GA2) for pin AB/4A and pin AB/8H ASM 343601.
- replace the FMGC-2 [1CA2] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- do a check and repair the
wiring between the MMR2(40RT2) and the FMGC2(1CA2) for pin AB/15F and pin AB/9A ASM 343601.
B. Do the test given in Para. 3.