MMR1 Test cannot be started
TASK 34-36-00-810-852-A
MMR1 Test cannot be started
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-36-00-740-120-A 4. Fault Isolation
Subtask 34-36-00-810-116-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:01 UTC
MMR1 Test cannot be started
1. Possible Causes
- MMR-1 [40RT1]
- LGCIU-1 [5GA1]
wiring between the MMR1(40RT1) and the LGCIU1(5GA1) - FMGC-1 [1CA1]
wiring between the MMR1(40RT1) and the FMGC1(1CA1)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-83-34-000-001 | Removal of the FMGC |
| AMM 22-83-34-400-001 | Installation of the FMGC |
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
| AMM 34-36-00-740-003 | BITE Test of the MMR |
| ASM 343601 | |
| AMM 34-36-31-000-001 | Removal of the ILS Receiver |
| AMM 34-36-31-400-001 | Installation of the ILS Receiver |
Subtask 34-36-00-740-120-A 4. Fault Isolation
Subtask 34-36-00-810-116-A
A. If the test gives the maintenance message
LGCIU1(5GA1)/FMGC1(1CA1)/ MMR1(40RT1):
Subtask 34-36-00-740-121-A LGCIU1(5GA1)/FMGC1(1CA1)/ MMR1(40RT1):
- do a check for a short to ground at pins AB/4AD, 15F of the MMR-1 ASM 343601.
- replace the MMR-1 [40RT1] AMM 34-36-31-000-001 and AMM 34-36-31-400-001.
- replace the LGCIU-1 [5GA1] AMM 32-31-71-000-001 and AMM 32-31-71-400-001.
- do a check and repair the
wiring between the MMR1(40RT1) and the LGCIU1(5GA1) for pin AB/4A and pin AB/6D ASM 343601.
- replace the FMGC-1 [1CA1] AMM 22-83-34-000-001 and AMM 22-83-34-400-001.
- do a check and repair the
wiring between the MMR1(40RT1) and the FMGC1(1CA1) for pin AB/15F and pin AB/9A ASM 343601.
B. Do the test given in Para. 3.