Loss of the CFDIU INPUT Bus on the MMR2
TASK 34-36-00-810-851-A
Loss of the CFDIU INPUT Bus on the MMR2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 34-36-00-740-118-A 4. Fault Isolation
Subtask 34-36-00-810-115-A
[Rev.8 from Aug 2018]
2026.04.04 04:33:01 UTC
Loss of the CFDIU INPUT Bus on the MMR2
1. Possible Causes
- MMR-2 [40RT2]
wiring of the CFDS DATA INPUT bus between the MMR2 (40RT2) and the first terminal block
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 34-36-00-740-003 | BITE Test of the MMR |
| ASM 343601 | |
| AMM 34-36-31-000-001 | Removal of the ILS Receiver |
| AMM 34-36-31-400-001 | Installation of the ILS Receiver |
Subtask 34-36-00-740-118-A 4. Fault Isolation
Subtask 34-36-00-810-115-A
A. If the test gives the maintenance message CFDIU(1TW)/MMR2(40RT2):
Subtask 34-36-00-740-119-A - replace the MMR-2 [40RT2] AMM 34-36-31-000-001 and AMM 34-36-31-400-001.
- do a check and repair the
wiring of the CFDS DATA INPUT bus between the MMR2 (40RT2) and the first terminal block for pins AB/1E, 1F of the MMR2 ASM 343601.
B. Do the test given in Para. 3.