W DOC AIRBUS | TSM A320F

Failure of the MMR1


TASK 34-36-00-810-842-A
Failure of the MMR1


1. Possible Causes
  • MMR-1 [40RT1]
  • wiring between the MMR receiver 1 and the first ground terminal
  • wiring between the circuit breaker (42RT1) and the MMR receiver 1
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 34-36-00-740-003
BITE Test of the MMR
ASM 343601
AMM 34-36-31-000-001
Removal of the ILS Receiver
AMM 34-36-31-400-001
Installation of the ILS Receiver
3. Fault Confirmation
Subtask 34-36-00-740-190-A ** ON A/C NOT FOR ALL
A. On the circuit breaker panel 49VU:
  • Do a reset of the MMR1 (40RT1) through the C/B 42RT1 for more than 10 seconds (open and close this C/B).
Subtask 34-36-00-740-100-A
B. Test
Do the BITE test of the MMR1 AMM 34-36-00-740-003.
4. Fault Isolation
Subtask 34-36-00-810-158-A ** ON A/C NOT FOR ALL
A. If the test does not give the maintenance message MMR1 (40RT1):
  • No maintenance action is necessary.
Subtask 34-36-00-810-102-A
B. If the test gives the maintenance message MMR1 (40RT1):
   (1) If there is no ground signal:
  • Do a check and repair the wiring between the MMR receiver 1 and the first ground terminal : pin AC/7 of the MMR receiver 1 ASM 343601
  • Install the MMR-1 [40RT1] AMM 34-36-31-400-001.
   (2) If there is a ground signal:
  • Remove the safety clip and the tag and close this circuit breaker:
    42RT1
  • Do a check for 115VAC between pins AC/7 and AC/9 of the MMR receiver 1.
  • Open, safety and tag this circuit breaker:
    42RT1
     (a) If there is no 115VAC:
  • Do a check and repair the wiring between the circuit breaker (42RT1) and the MMR receiver 1: pin AC/9 of the MMR receiver 1 ASM 343601
  • Install the MMR-1 [40RT1] AMM 34-36-31-400-001.
     (b) If there is 115VAC:
Subtask 34-36-00-740-101-A
C. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:33:00 UTC