W DOC AIRBUS | TSM A320F

ILS 2 Frequency cannot be tuned


TASK 34-36-00-810-829-A
ILS 2 Frequency cannot be tuned


1. Possible Causes
  • FMGC-2 [1CA2]
  • wiring of the FMGC OWN CB 1 bus from FMGC2 (1CA2) to the first terminal block
  • RMP-COM/NAV FREQ SEL, 2 [1RG2]
  • wiring of the DATA FROM FMGC bus from the COM/NAV FREQ SEL RMP2 (1RG2) to the first terminal block
  • wiring of the NAV FREQ DATA OUTPUT bus from the COM/NAV FREQ SEL RMP 2 (1RG2) to the first terminal block
  • MMR-2 [40RT2]
  • wiring of the FREQ/FUNCT SEL SYS PORT A bus from the MMR2 (40RT2) to the first terminal block
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-83-34-000-001
Removal of the FMGC
AMM 22-83-34-400-001
Installation of the FMGC
ASM 228602
ASM 231301
AMM 23-13-13-000-001
Removal of the Radio Management Panel (RMP)
AMM 23-13-13-400-001
Installation of the Radio Management Panel (RMP)
AMM 34-14-00-740-001
Interface Test of the IR
AMM 34-36-00-740-003
BITE Test of the MMR
ASM 343601
AMM 34-36-31-000-001
Removal of the ILS Receiver
AMM 34-36-31-400-001
Installation of the ILS Receiver
AMM 34-55-00-740-002
BITE Test of the VOR/MKR
3. Fault Confirmation
Subtask 34-36-00-740-082-B
A. Test
Do the BITE test of the MMR2 AMM 34-36-00-740-003.
4. Fault Isolation
Subtask 34-36-00-810-082-C
A. If the test gives the maintenance message FMGC2(1CA2)/RMP2(1RG2)/MMR2(40RT2):
  • on the center pedestal, on the RMP 2, push the NAV and the ILS pushbutton switches (the green LED on these pushbutton switches comes on)
  • do the BITE test of the MMR2 AMM 34-36-00-740-003.
   (1) If the test does not give the maintenance message
FMGC2(1CA2)/RMP2(1RG2)/MMR2(40RT2):
     (a) If the Interface test of the IR gives the maintenance message FMGC2(1CA2)/ADIRU1(1FP1):
       1 If the fault continues:
  • do a check and repair the wiring of the FMGC OWN CB 1 bus from FMGC2 (1CA2) to the first terminal block ASM 228602.
     (b) If the Interface test of the IR does not give the maintenance message FMGC2(1CA2)/ADIRU1(1FP1):
       1 If the fault continues:
  • do a check and repair the wiring of the DATA FROM FMGC bus from the COM/NAV FREQ SEL RMP2 (1RG2) to the first terminal block ASM 231301.
   (2) If the test gives again the maintenance message
FMGC2(1CA2)/RMP2(1RG2)/MMR2(40RT2):
     (a) If the BITE test gives the maintenance message
VOR 2 : NO DATA FROM CONTROL SOURCE:
       1 If the fault continues:
  • do a check and repair the wiring of the NAV FREQ DATA OUTPUT bus from the COM/NAV FREQ SEL RMP 2 (1RG2) to the first terminal block ASM 343601.
     (b) If the BITE test does not give the maintenance message
VOR 2 : NO DATA FROM CONTROL SOURCE:
       1 If the fault continues:
  • do a check and repair the wiring of the FREQ/FUNCT SEL SYS PORT A bus from the MMR2 (40RT2) to the first terminal block for pins AB/1C, 1D of the MMR2 ASM 343601.
Subtask 34-36-00-740-083-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:32:59 UTC